Schueco Enhanced Systems – SBE

Schueco bullet-resistant window and door systems have the designation AWS 90 BR and ADS 90 BR respectively and, using the same platform as the XR blast-resistant versions, are adapted to combat a ballistic threat. The windows and doors may also be specified with burglar resistance up to Class RC4 of EN 1627.
In addition, Schueco FW 50+ and FW 60+ façade systems can be specified for bullet and burglar resistance.
Bullet-resistant units must be designed in such a way that not only the frame profiles, glazing and hardware provide the relevant protection but also the fixings, installation and wall attachments.

Schueco blast protection façade Systems:

Schueco FW60+XR blast protection façade
Benefits
- Blast-resistant façade system tested in line with ISO 16933
– Based on the Schueco FW 60+ standard façade system
– High thermal insulation with Uf values up to 1.3 W/(m²K) in accordance with EN ISO 10077-2
– Tested unit dimensions of 3210 mm x 3485 mm for EXV19 (D)
– Tested unit dimensions of 3210 mm x 3485 mm for EXV15 (D)
– Tested module dimensions of 1565 mm x 2000 mm and 1565 mm x 1325 mm for EXV19 (D)
– Extended area of application based on calculations
– Combination with blast-resistant Schueco window and door systems AWS 90 XR / ADS 90 XR up to EXV19, on request
– System tested to product standard EN 13830
Schueco FW80+XR blast protection façade
Benefits
- Blast-resistant façade system tested in line with ISO 16933
– Façade system with a face width of 80 mm for the highest blast resistance requirements
– 35 mm deep glazing rebate to MoD guidelines
– High thermal insulation with Uf values up to 1.5 W/(m²K) in accordance with EN ISO 10077-2
– Tested unit dimensions of 3210 mm x 3485 mm for EXV15 (D)
– Tested module dimensions of 1565 mm x 2000 mm and 1565 mm x 1325 mm for EXV15 (D)
– Extended area of application based on calculations up to EXV12
– Combination with blast-resistant Schueco window and door systems AWS 90 XR / ADS 90 XR up to EXV19, on request
– System tested to product standard EN 13830

Schueco Enhanced Rated Window Systems:

Schueco AWS 90 XR blast protection window
Features & Benefits
- Blast-resistant window system tested in line with ISO 16933
– High thermal insulation with a basic frame depth of 90 mm
– 35 mm deep glazing rebate to MoD guidelines
– Enlarged insulation zone with foam-filled insulating bars
– Inward-opening turn-tilt window, tested vent size 1210 mm x 1840 mm, EXV19 (E)
– Area of application extended on the basis of calculations; maximum vent size 1450 mm x 1840 mm (EXV25)
– Combination with blast-resistant Schueco façade systems FW 60+ XR / FW 80+ XR on request
– Turn-tilt window with standard Schueco Avantec concealed fittings; vent weight up to 160 kg
– Uf value in accordance with EN ISO 10077-2: Uf = 1.6 W/(m²K)
Performance data
- System tested to product standard EN 14351: air permeability Class 4, EN 12207; watertightness 9A, EN 12208; wind resistance C5/B5, EN 12210

Schueco Enhanced Rated Door Systems:

Schueco AWS 90 XR blast protection door
Features & Benefits
- Blast-resistant door system tested in line with ISO 16933
– High thermal insulation with a basic frame depth of 90 mm
– 35 mm deep glazing rebate to MoD guidelines
– Single- and double-leaf outward-opening doors; tested maximum leaf size 1100 mm x 2250 mm, EXV19 (E)
– Area of application extended on the basis of calculations; maximum leaf size 1300 mm x 2500 mm (EXV25)
– Combination with blast-resistant Schueco façade systems FW 60+ XR / FW 80+ XR on request
– Doors up to maximum 300 kg leaf weight in conjunction with standard 3-part surface mounted hinges
– Uf value in accordance with EN ISO 10077-2: Uf = 2.3 W/(m²K)
Performance data
-System tested to product standard EN 14351: air permeability up to Class 2, EN 12207; watertightness up to Class 5A, EN 12208; wind resistance up to Class C3, EN 12210

Schueco Enhanced Classification and test requirements:

Classification and test requirements